A. SF6 Gas Detection Camera
- Cooled QWIP detector 320×256
- Startup time < 7 min
- No need to use laser
- Detecting at any background
- High performance LCD touch screen & Tiltable high resolution viewfinder
Parameter :
IMAGING PERFORMANCE | |
Field of view | 11° × 8.8°/ 24° × 18° |
Spatial resolution ( IFOV ) | 0.6 mrad |
Focus | Automatic / Manual |
Electronic zoom function | 1×~8× |
Responsivity | 0.001 ml/s |
Image frequency | 50 / 60Hz |
Detector type | Cooled detector 320×256 pixels |
Spectral range | 10.3~10.7 µm |
Startup time | <7 min |
IMAGE PRESENTATION | |
CCD camera performance | Build-in 5 million pixels digital camera |
Video output | AV |
External display | LCD with screen |
Viewfinder | Build-in TFT LCD with high resolution 800×600 pixels |
Palette | 8 palettes |
Gemi-vision | IR image overlap with visible light image |
MEASUREMENT | |
Temperature range | -20~+350 Optional extended to -40~+500 |
Accuracy | ±10~100or ±2%;+100°C |
Analysis | Automatic tracking Max / with temperature data; Delta T |
Emissivity correction | Variable from 0.01 to 1.0 |
VIDEO STORAGE | |
Type | Recording of 16 bit fully radiometric IR-video to SD-card |
LASER POINTER | |
Classification | Class 2 |
Type | Semiconductor AIGalnP Diode, Laser: 1 mW/635 nm red |
IMAGE STORAGE | |
Removable SD-Card | 32G |
BATTERY SYSTEM | |
Type | Li-ion, rechargeable, field replaceable |
Operating time | 2.5 hours continuous operation |
Charging system | 2-bay intelligent charger ( Optional: External power cable ) |
PHYSICAL CHARACTERISTICS | |
Weight (Include battery) | 2.4kg |
Size ( L×W×H ) | 292×148×138 ( mm ) |
ENVIRONMENTAL SPECIFICATION | |
Operating temperature range | -10 to +40 |
Storage temperature range | -40 to +70 |
Humidity | Operating and storage 10% to 95%, non-condensing |
Encapsulation | IP54IEC 529 |
Shock | Operational: 25G, IEC 68-2-29 |
Vibration | Operational: 2.5G, IEC 68-2-6 |
LAB TESTED TO DETECT A WIDE RANGE OF GASES | |
The type of gas | Sulfur Hexafluoride,Acetyl Chloride,Acetic Acid,Allyl Bromide,Allyl Chloride,
Allyl Fluoride,Ammonia (NH3),Bromomethane,Chloride Dioxide,Ethyl Cyanoacrylate, Ethylene,Furan,Hydrazine,Methylsilane,Methyl Ethyl Ketone,Vinyl Cyanide, Methyl Vinyl Ketone,Propene,Tetrahydrofuran,Vinyl Ether,Trichloroethylene, Uranyl Fluoride,Vinyl Chloride,Propenal |
- Cooled QWIP detector 320×256
- Startup time < 7 min
- No need to use laser
- Detecting at any background
- High performance LCD touch screen & Tiltable high resolution viewfinder
Parameter :
IMAGING PERFORMANCE | |
Field of view | 14.5°×10.8°/0.5m24°×18°/0.3m48°×36°/0.1m6°×4.5°/3m
Multiple option, quick replacement of lens at site |
Spatial resolution ( IFOV ) | 0.6 mrad |
Focus | Automatic / Manual |
Electronic zoom function | 1×~8× |
Responsivity | 0.001 ml/s |
Image frequency | 50 / 60Hz |
Detector type | Cooled detector 320×256 pixels |
Spectral range | 10.3~10.7 µm |
Startup time | <7 min |
IMAGE PRESENTATION | |
CCD camera performance | Build-in 5 million pixels digital camera |
Video output | AV |
External display | LCD with screen |
Viewfinder | Build-in TFT LCD with high resolution800×600 pixels |
Palette | 8 palettes |
Gemi-vision | IR image overlap with visible light image |
MEASUREMENT | |
Temperature range | -20~+350Optional extended to -40~+500 |
Accuracy | ±10~100or ±2%;+100°C |
Analysis | Automatic tracking Max / with temperature data; Delta T |
Emissivity correction | Variable from 0.01 to 1.0 |
VIDEO STORAGE | |
Type | Recording of 16 bit fully radiometric IR-video to SD-card |
LASER POINTER | |
Classification | Class 2 |
Type | Semiconductor AIGalnP Diode, Laser: 1 mW/635 nm red |
IMAGE STORAGE | |
Removable SD-Card | 32G |
BATTERY SYSTEM | |
Type | Li-ion, rechargeable, field replaceable |
Operating time | 2.5 hours continuous operation |
Charging system | 2-bay intelligent charger ( Optional: External power cable ) |
PHYSICAL CHARACTERISTICS | |
Size ( L×W×H ) | 292×148×138 ( mm ) |
ENVIRONMENTAL SPECIFICATION | |
Operating temperature range | -10 to +40 |
Storage temperature range | -40 to +70 |
Humidity | Operating and storage 10% to 95%, non-condensing |
Encapsulation | IP54IEC 529 |
Shock | Operational: 25G, IEC 68-2-29 |
Vibration | Operational: 2.5G, IEC 68-2-6 |
LAB TESTED TO DETECT A WIDE RANGE OF GASES | |
The type of gas | Sulfur Hexafluoride,Acetyl Chloride,Acetic Acid,Allyl Bromide,Allyl Chloride,
Allyl Fluoride,Ammonia (NH3),Bromomethane,Chloride Dioxide,Ethyl Cyanoacrylate, Ethylene,Furan,Hydrazine,Methylsilane,Methyl Ethyl Ketone,Vinyl Cyanide, Methyl Vinyl Ketone,Propene,Tetrahydrofuran,Vinyl Ether,Trichloroethylene, Uranyl Fluoride,Vinyl Chloride,Propenal |
- 320×256 pixels cooled MIRW detector
- Detecting at any background
- User-friendly operation
Parameter :
IMAGING PERFORMANCE | |
Field of view | 11° × 8.8°/ 24° × 18° |
Spatial resolution ( IFOV ) | 0.6 mrad |
Focus | Automatic / Manual |
Electronic zoom function | 50 / 60 Hz |
Responsivity | 0.001 ml/s |
Image frequency | 50 / 60 Hz |
Detector type | Cooled detector 320×256 pixels |
Spectral range | 3.2~3.5 µm |
Startup time | <7 min |
IMAGE PRESENTATION | |
CCD camera performance | Build-in 5 million pixels digital camera |
Video output | AV |
External display | LCD with screen |
Viewfinder | Build-in TFT LCD with high resolution800×600 pixels |
Palette | 6 palettes |
MEASUREMENT | |
Temperature range | -20~+350Optional extended to -40~+500 |
Accuracy | ±10~100or ±2%;+100°C |
Analysis | Automatic tracking Max / with temperature data; |
Emissivity correction | Variable from 0.01 to 1.0 |
VIDEO STORAGE | |
Type | Recording of 16 bit fully radiometric IR-video to SD-card |
LASER POINTER | |
Classification | Class 2 |
Type | Semiconductor AIGalnP Diode,Laser: 1 mW/635 nm red |
IMAGE STORAGE | |
Removable SD-Card | 32G |
BATTERY SYSTEM | |
Type | Li-ion, rechargeable, field replaceable |
Operating time | 2.5 hours continuous operation |
Charging system | 2-bay intelligent charger (Optional: External power cable) |
PHYSICAL CHARACTERISTICS | |
Weight (Include battery) | 2.4kg |
Size ( L×W×H ) | 292×148×138 (mm) |
ENVIRONMENTAL SPECIFICATION | |
Operating temperature range | -10 to +40 |
Storage temperature range | -40 to +70 |
Humidity | Operating and storage 10% to 95%, non-condensing |
Encapsulation | IP54IEC 529 |
Shock | Operational: 25G, IEC 68-2-29 |
Vibration | Operational: 2.5G, IEC 68-2-6 |
LAB TESTED TO DETECT A WIDE RANGE OF GASES | |
The type of gas | Benzene, Ethanol, Ethylbenzene, Heptane, Hexane, Isoprene, Methanol,
MEK, MIBK, Octane, Pentane, 1-Pentene, Toluene, Xylene, Butane, Ethane, Methane, Propane, Ethylene, Propylene |