1. Three Phase: W22 High Efficiency
- Description
-
High performance with maximum energy efficiency is the goal of the new W22 electric motor. High efficiency and Low cost of Ownership throughout the entire motor lifetime have been the basis for the W22 development. A design created to maximize performance and energy savings.
- New Cooling System
-
Designed to provide optimized air flow through all motor frames keeping low operational temperatures and assuring reliability and extended lifetime. The aerodynamic design of the fan cover optimizes effective airflow, thus minimizing losses due to the recirculation of air between fan and fan cover. The fan was designed to provide strength and reduced noise level. Motor terminal box and eyebolts are positioned on larger frames to allow better airflow.
The new W22 cooling system also contributes to:- Cooler bearing temperature extending relubrication intervals
- Lower Noise Level fulfilling the most demanding Health & Safety regulations
- Lower Overall Operational Temperature resulting in longer life
- Terminal Box
-
- Large internal space making connections more accessible to the user resulting in an easier cable handling and connection
- Terminal box can be mounted on top, left or right site of the motor using the same frame on the 447T and larger motors. Top mounting is optional on smaller frames
- Exclusive Bearing Sealing System
-
- Extends motor lifetime when operating in aggressive environments by protecting the motor against water and dust guaranteeing proper degree of protection
- Frame
-
Motor feet are solid providing a highly resistant structure against vibration. The frame design has points that can be used as provisions for vibration sensors as a standard feature.
Benefits from the new frame design:- Motor temperature reduction
- Eyebolts positioned for easy handling in the application
- Provision for vibration sensors – frame and endshields with provisions 90° displaced according to maintenance technical recommendations. Easier and more reliable vibration analysis
- Solid feet – Enhanced reliability when operating on high vibration applications and also provide easier alignment on installation
- Typical Applications
-
- Pumps
- Fans
- Crushers
- Conveyor belts
- Mills
- Centrifugal machines
- Presses
- Elevators
- Packaging equipment
- Grinders and others
- Standard Features
-
- Efficiency Certification number CC029A according to US Department of Energy Regulations
- Three-phase, 2, 4, 6 and 8 pole, 60Hz
- Voltage: 208-230/460V
- No derating for 50Hz operation up to 60 HP. For 75 HP and up, please contact our sales office
- Totally Enclosed Fan Cooled – TEFC (IP55) water tight and dust tight enclosure
- Squirrel cage rotor / Aluminum die cast
- WSeal® sealing on both endshields from frame 364T/5T up to 504/5T (586/7 frame fitted with Taconite Labyrinth as standard)
- Ball bearings are supplied as standard
- 1040/45 heat treated and stress relieved carbon steel shaft (4140 for 404/5T upwards in 4, 6 and 8 pole motors)
- Class “F” (?T = 80K) insulation for all frames
- Continuous flow insulation system with Class “H” wire (364/5T and larger)
- WEG submerged and bake system with Class “H” wire (324T and smaller)
- Temperature rise limited to Class “B” (80K) @FL
- NEMA ratings design “B”
- Service Factor: 1.25 up to 100 HP 1.15 from 125 HP and up
- Continuous duty (S1)
- 104ºF (40ºC) ambient temperature
- Altitude: 3300 ft (1000m
- NPT threaded terminal box
- Stainless steel nameplate AISI 316 with laser etching
- Paint: Synthetic enamel alkyd resin base (240 hours minimum ASTM B117 salt spray test)
- Color: RAL 5009 – Blue
- Fitted with closed rubber drain plug (automatic drain when open)
- Regreasable bearings, with grease fittings in DE and NDE bearings (254T and larger)
- Gasketed conduit box
- CLASS I, DIV. 2, GROUPS A, B, C & D:
- T3 for 1.25 SF motors up to and including 404/5T frames
- T3 for 1.15 SF motors up to and including L449T frames
- T2C for 1.15 SF motors on 586/7
- T2B for 1.0 SF motors on frames L449T and larger
- These temperature codes are not valid for motors operating with VFD and/or with installed space heaters
- CLASS II, DIV. 2, GROUPS F & G:
- T5 for 1.25 SF motors up to and including 184T frames
- T4 for 1.25 SF motors from 213T up to and including 404/5 frames
- T3C for 1.15 SF motors up to and including 586/7 frames
- T4 for 1.0 SF motors on frames L449T, 586/7 and 588/9
- These temperature codes are not valid for motores operating with VFD and/or with installed space heaters
- MGI Part 31 rating for use with VFD – 20:1 constant torque speed range up to 250 HP. Speed range with constant torque can be extended with optional Blower kit
- Optional Features
-
- Special voltages
- Specially designed shaft
- Threaded NDE shaft side for encoder assembly
- Space heaters (standard on 586/7 frames)
- Labyrinth tachonite seal available for all ratings
- Thermostats or RTD’s (Pt-100)
- Additional terminal box
- Drip cover (canopy) for shaft down applications
- Cable glands
- C-Face and NEMA D flanges for all ratings
- C-Face fan cover for accessories or Double C-Face mounting
- Roller bearing models available
- Special epoxy painting
Description
WEG High Efficiency motors are specifically designed to meet or exceed all EPAct requirements for energy efficiency. They are certified by the Department of Energy with our Certificate of Compliance number CC029A.
These motors are designed for environments where dirt and moisture are minimal. Design “B” torque and high efficiency design from 254 through 444/5T frames (design “A” for frames 447/9T and 5010/11T). These motors are specifically designed to provide maximum ventilation and heat dissipation. “C” and “D” flange available.
Applications
- Pumps
- Fans
- Kneader and mixer machines
- Cutter and sawing machines
- Pressing machines
- Industrial equipment
- Conveyors
- Blowers
- Compressors
- Machinery
- Cranes
- Packaging Equipment
Standard Features
- Three-phase, II and IV pole, 60Hz
- Voltage:
- 208-230/460V (for frames 254T to 444/5T)
- 460V (for frame 447/9T and up)
- NEMA dimensions
- NEMA Design “B” (NEMA Design “A” for frames 447/9T to 5010/11T)
- Service factor: 1.15
- Class “F” insulation for all frames
- Continuous Duty (S1), 104 °F ambient (40ºC)
- F1 mount (also available flanged motors)
- Paint: Synthetic enamel alkyd resin base
- Color: RAL 5009 – Blue
- NPT threaded terminal box
- Stainless steel nameplate – laser etched
- Regreasable bearings
- Ball bearings
Optional Features
- Cable glands
- Special voltages
- Terminal block
- Cast iron NEMA “C” flange, available for frames 254T up to 447/9T or “D” flange, available for all frames
- Specially designed shaft
- Second shaft end
- Thermistors, thermostats or RTD”s (PT100)
- Roller bearings on drive end
- IEC metric frames (on request)
3. Close Coupled Pump: Three-Phase – W22 “JM” Type – TEFC – High Efficiency
- Application
-
Ideal for close coupled pumps, the new W22 JM Type High Efficiency brings all concepts and benefits from the new W22 motors platform allied to the highest efficiency levels currently available. Specially developed line for industrial and commercial pumping applications, its totally enclosed frames permit these motors to operate in moist or dusty atmospheres.
- Water pumping
- Process
- Transfer and circulating pumps
- Standard Features
-
- High Efficiency Level according to NEMA MG-1
- Three-phase, 60 Hz
- Degree of protection: IP55 – TEFC – Totally enclosed fan cooled
- Rated output: 1 HP to 75 HP
- Number of poles: 2 and 4
- Frame sizes: 143JM to 364/5JM
- FC-200 Cast iron frames
- Voltage: 208-230/460, 460V or 575V
- Service Factor: 1.25
- F-1 mount
- Steel made fan cover for frames 143JM to 215JM and cast iron made for 254JM and above
- Automatic drain plastic plug for frames 143JM to 215JM and rubber closed drain plug 254JM and above
- V’ring seals for frames 143JM to 326JM and Oil seal for frame 364/5JM
- Class “F” insulation with class “B” (80ºC) temperature rise
- Simple grounding (T-box interior and frame) for frames 143JM to 326JM and double grounding + additional (1 at T-box and 3 at frame) for frame 364/5JM
- Grease nipples for frame 364/5JM
- Continuous Duty (S1)
- Painting plan: 207A for frames 143JM to 215JM and 203A for frame 254JM and above
- Color: RAL 5009 – Blue
- Without thermal protection
- Design B
- Optional Features
-
- Degree of protection: IPW55, IP56, IP65 and IP66
- Other voltage configurations
- Thermal protection: Thermistors, Thermostats or PT-100
- Space heaters
- Additional terminal box for accessories
- Cable glands
- 6 or 12 pins BMC terminal block
- Cable glands
- Grease nipple for frames 254JM to 326JM
- Stainless steel shaft
- Cast iron fan cover for frames 143JM to 215JM
- Other optional features under request
- Notes
-
- Motors are tested according to IEEE 112 std. – method “B” or C390 CSA
- WEG also can provide IEC metric frame, cast iron, TEFC. Please ask for specific catalog.
4. Jet Pump – NEMA 56: Three-Phase – Keyed – TEFC (IP55)
Description
Applications
- Commercial and Industrial pumps
- Residential pumps (jacuzis, pools, hot tubs)
- Jet pump motor system
- Hydraulic pumps
Standard Features
- Three-phase, II pole, 60Hz
- Voltage: 208-230/460V
- Squirrel cage rotor
- Ball bearings
- Totally Enclosed Fan Cooled (TEFC)
- Service factor according to NEMA standard MG 1-18.329
- Insulation Class “F” (155 °C)
- Standard: NEMA-MG 1-18.326
- Rotation: Reversible
- Stainless steel shaft end
- Color: Munsell N1 (Black)
Optional Features
- IV Pole
- Class “F” insulation
- Special voltages
- Drip cover
- Rotation: Form C: Reversible
- Automatic Overload Protection
- Other mounting configurations
5. P-Base Motors: High Efficiency
Description
Applications
Normal thrust in-line pump applications
- Waste water treatment plants
- Petro chemical industries
- Pulp and paper mills
- Agricultural irrigation
Standard Features
- Three-phase, II & IV pole, 60Hz
- Voltage: 208-230/460, 460 or 575 V
- HP type: from frames 143HP up to 445HP
- HPH type: frames 284/6HPH and 404/5HPH
- Squirrel cage rotor / Aluminum die cast
- Totally Enclosed Fan Cooled – TEFC (IP55)
- V-ring slingers on both endshields
- Cast iron frame
- Ball bearings
- Class “F” insulation for all frames
- Service factor for High Efficiency:
– 1.25 up to 100HP
– 1.15 from 125HP and up
Service Factor for Standard Efficiency: 1.15 - Temperature rise: Class “B” (80ºC)
- Continuous Duty (S1)
- 104ºF (40ºC) ambient temperature
- Altitude: 3300 ft (1000 m)
- 1045 carbon steel shaft
- Usual mounting: V1 – footless
- Stainless steel nameplate
- Paint: Enamel alkyd resin base
- Color: RAL 7022 – Dark Gray (Standard Efficiency)
Color: RAL 5009 – Blue (High Efficiency) - NPT threaded terminal box
- Automatic drain plugs
- Regreasable bearings system (frames 254HP and up)
- Thermistors from frames 324HP and up
- Drip cover (canopy)
Optional Features
- Cable glands
- Special voltages
- Space heaters
- Second shaft end
- Thermostats or RTD’s (PT100)
- Additional terminal box
- Stainless steel shaft
NOTES
Motors are tested according to IEEE 112 std. – method “B” or C390 CSA
High Efficiency motors are suitable for Inverter Duty.
6. Three-Phase: NEMA 56 Frames – ODP
Description
Applications
- Pumps
- Air Conditioning equipment
- Farm Equipment
- Conveyors
- Business machines
- Gear reducers
- Compressors
- Tools
- Fans and blowers
- Packaging equipment
Standard Features
- Three phase, II, IV or VI pole, 60Hz
- Squirrel cage rotor
- NEMA dimensions
- High starting torque
- Service Factor 1.15 or better
- Ball bearings
- Color: RAL 7022 (Dark Gray)
- Class ‘B’ insulation (ODP)
- Continuous duty, 40ºC ambient
- V-ring slinger in both endshields
- Designed to operate in any position
- Class I, Div II. Groups B, C & D
- Class II, Div II. Group F. CSA: 50962
Optional Features
- Class ‘F’ insulation
- Flange mount
- Special voltages
- Specially dimensioned shaft
- Second shaft end
- Stainless steel shaft
- Footless
- Other mounting configurations